Water Separator AMG
| Series/CAD |
Air flow capaciy L/min (ANR) |
Port size |
AMG CAD 3D CAD |
300 to 12000 |
1/8 to 2 |
| Features |
- Compressed air without water can be obtained.
- Water drop removal ratio: 99%
|
Main Line Filter AFF
| Series/CAD |
Filtration (μm) |
Air flow L/min (ANR) |
Port size |
AFF CAD 3D CAD |
3 (Filtration efficiency 99%) |
300 to 42000 |
1/8 to 4B flange |
| Features |
- Can remove impurities such as oil, water and foreign matter in compressed air and can improve the function of a dryer in the downstream, extend the life of precision filter, and prevent trouble with the equipment.
|
Mist Separator AM
| Series/CAD |
Filtration (μm) |
Air flow L/min (ANR) |
Port size |
AM CAD 3D CAD |
0.3 (Filtration efficiency 99.9%) |
300 to 12000 |
1/8 to 2 |
| Features |
- Can separate and remove oil mist and remove solid particles such as rust or carbon of 0.3 μm or larger.
|
Micro Mist Separator AMD
| Series/CAD |
Filtration (μm) |
Air flow L/min (ANR) |
Port size |
AMD CAD 3D CAD |
0.01 (Filtration efficiency 99.9%) |
200 to 40000 |
1/8 to 6B flange |
| Features |
- Can separate and remove aerosol state oil mist and remove carbon or dust of 0.01 μm or larger.
- Should be used as a prefilter of compressed air for precision instruments or clean room requiring high levels of clean air.
|
Micro Mist Separator with Pre-Filter AMH
| Series/CAD |
Filtration (μm) |
Air flow L/min (ANR) |
Port size |
AMH CAD 3D CAD |
0.01 (Filtration efficiency 99.9%) |
200 to 12000 |
1/8 to 2 |
| Features |
- Integrates Series AM and Series AMD to achieve a reduction in installation space and to reduce piping installation labor and costs.
- Can separate and remove aerosol state oil mist and remove carbon or dust of 0.01 μm or larger.
- Should be used as a prefilter of compressed air for precision instruments or clean room requiring high levels of clean air.
|
Super Mist Separator AME
| Series/CAD |
Filtration (μm) |
Air flow L/min (ANR) |
Port size |
AME CAD 3D CAD |
0.01 (Filtration efficiency 99.9%) |
200 to 12000 |
1/8 to 2 |
| Features |
- Can separate and absorb aerosol state fine oil particles and change the oil lubricating compressed air to oilless equivalent air.
- Should be applied for filtration of compressed air requiring a high degree cleanliness such as the compressed air for coating lines, for clean rooms and for equipment that must avoid oils.
|
Odor Removal Filter AMF
| Series/CAD |
Filtration (μm) |
Air flow L/min (ANR) |
Port size |
AMF CAD 3D CAD |
0.01 (Filtration efficiency 99.9%) |
200 to 40000 |
1/8 to 2 |
| Features |
- Efficiently removes odors in compressed air with an activated carbon element. The unit is designed for clean rooms where odors must be removed.
- Activated carbon element with large filtration area.
- Easy replacement and installation of elements.
|
Clean Gas Filter SF
| Type |
Series/CAD |
Operating pressure |
Filtration |
Cartridge type disc |
SFA100/200/300 CAD |
Max.1.0 MPa (Vacuum: 1.3 x 10-6 kPa) |
0.01 μm (Filtration efficiency 99.99%) |
Cartridge type straight |
SFB100 CAD |
Max.1.0 MPa (Vacuum: 1.3 x 10-6 kPa) |
|
Features |
- Cartridge type allows element replacement.
|
Disposable type straight |
SFB300 CAD |
Max.15 MPa (Vacuum: 1.3 x 10-6 kPa) |
0.01 μm (Filtration efficiency 99.99%) |
Disposable type multiple disc |
SFC100 CAD |
Max.1.8 MPa (Vacuum: 1.3 x 10-6 kPa) |
|
Features |
- Compact disposable type for semiconductor industry
|
Clean Air Filter / Hollow Fiber Element SFD
| Series/CAD |
Type |
Operating pressure |
Filtration |
| SFD100 CAD |
Disposable type (Irreplaceable element) |
MAX.1.0 MPa |
0.01 μm (Filtration efficiency 99.99%) |
| SFD200 CAD |
Cartridge type (Replaceable element) |
| Features |
- Built-in hollow fiber element
- Pressure drop: 0.03 MPa (Inlet pressure 0.7 MPa, Max. flow rate)
- Conforms to RoHS reduction of environmentally detrimental chemicals.
|
Clean Air Module LLB

Note: Inlet air conditions ISO 8573-1 Quality grade: Equivalent to 1.4.1 to 1.6.1
| Series/CAD |
Fluid |
Set pressure |
Flow range L/min (ANR) |
| LLB3 CAD |
Clean air N2gasNOTE) |
0.05 to 0.4 MPa |
5 to 100 |
| LLB4 CAD |
50 to 500 |
| Features |
- Clean equipment modularized (Reduction of piping labor/Space-saving)
- Clean air is easily available.
- Nominal filtration rating: 0.01 μm (Filtration efficiency 99.99%)
- Wetted parts: Grease-free, Silicone-free
- Assembled in a clean room, shipped and packed in a duplicate package
- 24 combinations available
|
Auto Drain Valve AD
| Model/CAD |
Port size |
Drain discharge port size |
| AD402 CAD |
1/4,3/8,1/2 |
3/8 |
| AD600 CAD |
3/4,1 |
3/4,1 |
| Features |
- Drainage is automatically discharged.
|
Motor Operated Auto Drain ADM
| Model/CAD |
Power consumption (W) |
Port size |
| ADM200 CAD |
4 |
IN |
3/8,1/2 |
| OUT |
3/8 |
| Features |
- Reliably discharges even highly viscous drainage.
|
Heavy Duty Auto Drain ADH
| Model/CAD |
Port size |
Auto drain |
| ADH4000 CAD |
1/2 |
Float type |
| Features |
- Easy maintenance.
- Possible to maintain easily without removing pipes.
- No need for electric power and no waste of air.
- Float style drain allows automatic draining without electric power.
|
Differential Pressure Gauge GD40
| Model |
Accuracy |
Scale range |
| GD40 |
±0.006 MPa |
0 to 0.2 MPa |
| Features |
- The pressure differential at the inlet and the outlet of compressed air equipment can be viewed at a glance on the pressure differential gauge.
It is ideal for the maintenance control of filters.
- Can be installed easily by merely providing a bypass circuit.
- Provided with a protective cover to prevent hazards.
|