Inline Vacuum Filters - Series ZFC [Specifica-L-Wy

 
Model No. Port size
(applicable
tube O.D.)

IN side, OUT side
*Recommended
flow rate
/min (SCFM)
Weight
g

(oz)
Metric Size ZFC-100-04B 4 10 (0.35) 11
(0.41)
ZFC-100-06B 6 20 (0.70)
ZFC-200-06B 6 30 (1.05) 21.5
(0.76)
ZFC-200-08B 8 50 (1.75)
Inch Size ZFC-101-03B 5/32" 10 (0.35) 11.5
(0.41)
ZFC-101-07B 1/4" 20 (0.70)
ZFC-201-07B 1/4" 30 (1.05) 21.5
(0.76)
ZFC-201-09B 5/16" 50 (1.75)

* Flow rate when initial pressure drop is 0.003MPa (0.44psi) or less.
(See Flow Rate Characteristics.)


Fluid

Air, Nitrogen

Operating pressure

100 to 0kPa (-14.5 to 0psi)

Withstand pressure

0.5MPa (72.5psi)

Operating and ambient
temperature range

0 to 60°C (32° to 140°F)
(with no freezing)

Filtration degree

10µm

Element differential pressure resistance

0.15MPa (21.75psi)

Applicable tubing material

Nylon, Soft nylon, Polyurethane,
Soft polyurethane

Note: Do not use in a line where pressurized condition is maintained, since the body may be damaged.


 
     
 
facebook twitter instagram linkedin