R-800 Series Miniature Precision Pressure Regulator - 1/8 NPT ports

 

U.S. Patent No. 5,358,004
The R-800 series regulators offer high performance in a compact size. 1/8-27 NPT ports allow the use of a wide range of fittings for design flexibility.


FEATURES:
Twenty turn hysteresis free adjustment allows pressure settings to 1" WC resolution.

Four adjusting styles allow maximum design flexibility. The non-rising stem is available with an attractive knob, or plain, allowing installation of OEM knobs. Also available is a flush adjusting shaft, for applications where pressure settings are changed less frequently. Factory pre-set "tamperproof" models are also available. (See drawings)

Mounting options include panel mount, through a 9/16" hole (nut included), and base mount, through 4 holes 0.125" dia. (See drawings)

Plastic construction - corrosion resistant wetted materials.

High accuracy - Low effect of supply variation on output.

Low cost - Perfect for OEM applications.

 

Applications:
Medical Equipment
 - Oxygen Concentrators
 - Ventilator / Respirators
 - Nebulizers
Air Bearings
HVAC Systems
Custom Machinery
Robotics

Options
Oxygen Clean
Factory Pre-set

R-800 Series
REGULATOR TYPE
Constant Bleed, Relieving
WETTED MATERIALS Polysulfone, Buna-N, EPDM, Acetal, Polyurethane, Stainless steel
SUPPLY CONSUMPTION < 9 SCIM (150 cc/min) @ 30 PSI (207 kPa) supply
< 21 SCIM (350 cc/min) @ 100 PSI (689 kPa) supply
MAX SUPPLY 150 PSI (1.03 MPa)
TEMPERATURE RANGE 40° - 150° F (4° - 66° C)
EFFECT OF SUPPLY VARIATION < 0.05 PSI (0.35 KPa) per 10 PSI (68.9 kPa) supply change when dead-ended
REPEATABILITY < +/- 0.1 PSI (0.69 kPa) when supply is removed and re-applied
SENSITIVITY 1" H2O (0.25 kPa)
MAXIMUM FLOW 2.5 cu.ft./min. (70 LPM)
RELIEF CAPACITY 0.5 cu.ft./min. (14 LPM) with outlet 5 PSI (34.5 kPa) above set-point
RECOMMENDED FILTRATION 5 micron

R-810 Series
REGULATOR TYPE

Non-bleed, non-relieving

Note: R-810 series regulators are not recommended for dead-end, no flow applications. A downstream relief of at least 20 cc/min is recommended.
REPEATABILITY < +/- 0.25 PSI (1.72 kPa) when supply is removed and re-applied
EFFECT OF SUPPLY VARIATION < 0.1 PSI (0.69 kPa) Per 5 PSI (34.5 kPa) supply change
All other specifications remain the same as the R-800 Series
R-820 Series
REGULATOR TYPE
Non-bleed, relieving
SUPPLY CONSUMPTION (see note) < 0.3 SCIM (5 cc/min.)
REPEATABILITY < +/- 0.25 PSI (1.72 kPa) when supply is removed and re-applied
EFFECT OF SUPPLY VARIATION < 0.1 PSI (0.69 kPa) per 5 PSI (34.5 kPa) supply change
SENSITIVITY 2" H2O (0.5 kPa)
All other specifications remain the same as the R-800 Series

Note: R-820 series regulators have "near zero" bleed to atmosphere under normal operating conditions. Should any overshoot, or downstream pressure increases occur, the unit will relieve only what is necessary to stabilize the pressure setting.
Important: Proper filtration is a must to maintain correct operation of the R-820 Series. Airtrol Components Inc. cannot guarantee perfect "non-bleed" operation under any circumstances.
Consult with an Airtrol Application Engineer for more information.

 

Model Number
Description
R-800-XX-W/K Precision regulator with adjusting knob
R-800-XX-W/S Precision regulator with 1/4" adjusting shaft
R-800-XX-W/OS Precision regulator with slotted adjusting shaft
R-801-XX Factory pre-set regulator

R-810-XX-W/K Non-bleed, non-relieving with adjusting knob
R-810-XX-W/S Non-bleed, non-relieving with 1/4" adjusting shaft
R-810-XX-W/OS Non-bleed, non-relieving with slotted adjusting shaft
R-811-XX Non-bleed, non-relieving, pre-set regulator

R-820-XX-W/K Non-bleed, relieving with adjusting knob
R-820-XX-W/S Non-bleed, relieving with 1/4" adjusting shaft
R-820-XX-W/OS Non-bleed, relieving with slotted adjusting shaft
R-821-XX Non-bleed, relieving, pre-set regulator
XX

Range
(PSI)

0.5-3.5
0.5-10
0.5-30
0.5-60
0.5-90




Please specify range when ordering. For factory pre-set models, specify set-point, input pressure, and flow, if not dead-ended.
.

 